Sep 30, 2019 · YouTube™ Video: Oxygen not included - How to buil

Posted April 29, 2022. If you want to turn a cool steam vent output into cool (<20°C) Oxygen, here is what I quickly put together : Steam comes out 110°C, gets heated by AT, then turned into 95°C water to feed the electrolyzers. 95°C Oxygen comes out and gets cooled in the radiator over the turbine; this radiator is the AT coolant loop.Great video! But I the currently have a steam vent in my seed that outputs 3.2Kgs of steam at 500°. That's alot of heat. Right now, I have 2 problems: The central part is easilly reaching 250°, which leads to the steam turbine to not be 100% efficient. My system hasn't reached equilibrium, and I fear I might not be deleting enough heat right now.

Did you know?

Cool Steam Vent Taming : Tutorial nuggets : Oxygen not included Francis John 94.1K subscribers 449K views 3 years ago How to extract water from a cool steam vent. It is easier to...Find out how to do an inexpensive bathroom remodel that includes replacing the toilet, vanity, sink, and accessories, tiling the floor, and adding a vent fan. Expert Advice On Improving Your Home Videos Latest View All Guides Latest View Al...The reason I ask is because if you build the hydrogen generators out of steel, you can use radiant pipes with the hot hydrogen to equalize the temperature in the room (must be insulated) to about 135° and delete the heat. Not sure just how much hydrogen the vent actually produces, but it could be a great source of power along with the steam ...Hydrogen vent taming. This design pumps out 130-140 degree hydrogen. Even if started in a vacuum, it won't overheat. Atmo Sensor (upper left): Above 4000g. Atmo Sensor (below gas pump): Above 1000g. Thermo Sensor: Below 135. Use steel for the Gas Pump. Note: Radiant liquid pipes help cool the steam turbine.Oxygen Not Included • Cool Steam Vent Setup Taming a cool steam vent seems like a good idea at first, free water and power. However many players quickly …Since heating steam wastes energy, a Self-powered Cool Steam Vent Tamer needs to minimize the amount of energy used heating steam. Hence very targeted steam tile heating using the Conductive Wire Bridges to conduct heat strategically. AT first, I just let it cool into water naturally, then pipe in the hot water directly into electrolyzers. It's much easier to cool the oxygen than the water. Later on I add a cooling loop to cool the oxygen, which also chills a cold box that I used to cool the steam into water. It's at this point that I box the steam vent in an insulate it. Sep 30, 2019 · YouTube™ Video: Oxygen not included - How to build: Steam Vent Tamer! Hey everyone! Here is my design for taming hot steam vents, I hope you find it useful! ----------------------------------- Timestamp for priming the thermo sensor: Recommend watching at 0.5x if its... Assuming the design at 1:27 is the final one then it seems overly ... To cool down water you can use aquatuners. This devide decrease incoming liquid temperature by 14C and equivalent of that heat removed is spread around the aquatuner. So it doesn't remove heat, it just moves it from liquid to enviroment surrounding. You need to figure out a way to keep aquatuner from overheating.If you are using water for lice loaf, got your electrolyzers set up early, etc.... you could easily be out of water. Especially if you didn't find it for the first 100-150 cycles. dtylertx • 5 yr. ago. tip: save electricity and water, turn the lice into picked meals.I found a cool steam vent but where i have the frozen core modifier my base is ... Cuz I still need to set up a eletrolizer set up but idk if it is worth doing that cuz my base is good on oxygen rn. 2. ... Community for the space-colony simulation game Oxygen Not Included, developed by Klei. 169k. Mouth Breathers. 334. Suffocating. Created Jun ...The video you watched might have been a normal steam vent, which is hotter (500ºc). Cool steam vents produce steam at 110ºc, which is really close to its condensation point (99.4ºc), so it turns into water really fast. Just surround it with insulated tiles, so it doesn't heat the surrounding area, then the only problem you will have is to ...Apr 3, 2021 · Hello everyone! Today, we're hooking up our first Steam Vent in the base to resupply our water. Hope you enjoy!:)Oxygen Not Included is a space colony simula... In either case, put gas pressure sensor right next to bottom left corner of the gas pump, so it only turns on if pressure is >=500g. Otherwise you're wasting power. Filtration matters. Wrong gas will break your gas generator. Low tech solution: Gas filter for simple, safe but energy hungry filtration.Jan 14, 2021 · Yeah, it's a game that's meant to be fun and simplified, which is exactly the opposite of what the 125C steam turbine and 85C tepidizer mark do. It makes things unnecessarily tedious. Cool steam vent would be a godsend with 100C mark, but it's by far one of the worst and most hated geysers for getting water in the game. The reason I ask is because if you build the hydrogen generators out of steel, you can use radiant pipes with the hot hydrogen to equalize the temperature in the room (must be insulated) to about 135° and delete the heat. Not sure just how much hydrogen the vent actually produces, but it could be a great source of power along with the steam ...This build works best with an Infectious Polluted Oxygen Vent and will output Oxygen slightly colder than the Vent output. For a Hot Polluted Oxygen Vent, you might want to modify the build a bit to passively cool the Polluted Oxygen with a Steam Turbine beforehand.Hello Everyone! Recently i have seen a lot of Steam Vent tamer. Even power neutral onces.So I decided to come up with my very own version of a cool steam ven...Jan 20, 2022 · The self-cooled power positive cold steam vent tamer.Cold Steam Vent Tamer short: https://youtu.be/HE9VoS65iK8Patreon: https://www.patreon.com/LumaplaysSave...

When the water exits the steam turbine it's still really hot (like 95c hot) and since an electrolyzer will always output hydrogen and oxygen at at least 70c, you never want to feed one with cooler than 70c water, so might as well use the hottest water available in the game and then cool the oxygen (not the hydrogen, because why would you unless you're …Assuming the steam is coming out at 500C, that’ll “burn” 375C as you feed the steam through. That’ll produce an absurd amount of wasted power and extra heat on the turbine. To fix this, you need to cool your steam down to around 250C-300C. To do this, you’ll want to run the steam past enough thermal mass to cool it down.Water from steam vents. Playing the spaced out DLC and my main base is running very low on water. I have 2 cool steam vents, the only problem is that the heat will kill my crops. I have 2 ideas on how to deal with it: 1. Using a hydrogen vent I can power some Thermo aquatuners to cool the water. 2.Oxygen Not Included – Taming the Hydrogen Vent Guide (Easy Method) July 30, 2021 0. The purpose of this guide is to present a method to tame the Hydrogen Vent in a simple way that can be built with mid-game technologies and materials. Simplicity, reliability and low-cost are the focus of this design. Contents [ Hide]Got a Submerged Cool Steam Vent? Tap that water supply easily!Thanks to RoCoi for drawing my attention to the airflow tile expoit.https://youtu.be/xOv5-pA5V...

Angpaur Feb 13, 2020 @ 11:48pm. You should use the cool steam vent in all machines/places that doesn't really care about input temperature but outputs hot stuff. Electrolyzer was already mentioned. Another good example is oil well. It is suggested to send hot water there as the building will always output oil at 90C.Harvest water from cool steam vents econmically with a gold amalgam aquatuner and a steam turbine.Not mentioned in the video but later in the game super cool...You'll need plastic to build this. (I said "early game" in the video, it's not really, because plastic.) This build heats the steam and feeds it to steam tur...…

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. AT first, I just let it cool into water naturally, then. Possible cause: 1. DimaB77 • 2 yr. ago. In my last article (getting water), I studied the volume of each.

1. DimaB77 • 2 yr. ago. In my last article (getting water), I studied the volume of each volcano's eruption. On average, a vent of hot steam erupts 2.2kg/sec of steam. Every turbine port absorbs 400gr/sec steam x 7 = 2.8kg/sec steam + 360kg what will fit in the room. That's a lot more than the volcano is erupting.The first answer would obviously be filtering it and using it as a water source, but I already found two cool steam geysers that should provide plenty of clean water without the need for refinement. Of course, I could also use it for fertilizer production, but even with ten fert refineries I have more pwater than I know what to do with.Harvest water from cool steam vents econmically with a gold amalgam aquatuner and a steam turbine.Not mentioned in the video but later in the game super cool...

Yeah, it's a game that's meant to be fun and simplified, which is exactly the opposite of what the 125C steam turbine and 85C tepidizer mark do. It makes things unnecessarily tedious. Cool steam vent would be a godsend with 100C mark, but it's by far one of the worst and most hated geysers for getting water in the game.Cool Steam Vent Tamer using Bathroom Water - Oxygen Not Included 2LegitCity 2.19K subscribers Join Subscribe 118 8.7K views 1 year ago Cool Steam Vent Tamer using your extra...

For that reason, on un-tuned vents, it is 449K views 3 years ago How to extract water from a cool steam vent. It is easier to cool the water down than to heat it up for a steam turbine. In this quick tutorial …Steam Vent is a Geyser which provides a renewable supply of high-temperature Steam (and thus Water). Like all gas vents, it will overpressurise and stop producing if the surrounding pressure reaches 5kg. Steam Vents produce an enormous amount of Heat due to their high output temperature (500 °C) and the high specific heat of Steam - an average Steam Vent will produce a whole-period average of ... Community for the space-colony simulation gaIt's a much better idea to use hot salt water geyse A fresh build (inc Steam Turbine) onto a Hot Polluted Oxygen Vent didn't have any overheating, and the water/metal tiles initial cool temperature made sure the Polluted O2 didn't cause any overheats. You could put a couple of Temp Shift Plates in there to speed the heat transfer as well. Mar 16, 2022 · BierTier explains EVERY VENT/GEYSE If there's no steam, no water will replenish the cooling loop. But the temp sensor is in the oil, not in the vacuum, so the aquatuner can continue running regardless of the chamber having steam or not. So if the aquatuner is running and no water is being added to the loop, but the cold sensor can eject water, you could drain the entire loop ... Oxygen Not Included 2017 Browse game Gaming BrowFor the cool steam vents, run a simple condenseTaming a 500 degree hydrogen vent.End Screen Hello Everyone! Recently i have seen a lot of Steam Vent tamer. Even power neutral onces.So I decided to come up with my very own version of a cool steam ven... Since heating steam wastes energy, a Self-powe Got a Submerged Cool Steam Vent? Tap that water supply easily!Thanks to RoCoi for drawing my attention to the airflow tile expoit.https://youtu.be/xOv5-pA5V...Steam Vent is a Geyser which provides a renewable supply of high-temperature Steam (and thus Water). Like all gas vents, it will overpressurise and stop producing if the surrounding pressure reaches 5kg. Steam Vents produce an enormous amount of Heat due to their high output temperature (500 °C) and the high specific heat of Steam - an average Steam Vent will produce a whole-period average of ... No Space materials. Just 400Kg of steel. 1[Hi All, I'm having problems keeping my base area cool due tFeatures: Self-cooling. The Steam Turbine cools itself. In the original build, if the Steam Pressure ever reached 1000kg+ per tile, the Liquid Vents would overpressurize, thus ceasing DFD, thus making the Vent also overpressurize. I prevented it by trapping a few grams of Oxygen (or any gas lighter than steam) in the tile where the Liquid Vents are. Now, they are inoverpressurable. No wasted water.